PB-9250J-110V: Industrial-Grade Railway Intelligent Supercapacitor-Based Uninterruptible Power Backup Module 110V 9250Ws
PB-9250J-110VView SuperCap UPS Backup Modules
Neousys' PB-9250J-110V is a newly designed SuperCAP UPS accepting 110V DC input for fast-growing railway applications. Composed with eight 370F supercapacitor, PB-9250J-110V provides 9250 watt-second stored energy to sustain back-end system from seconds to minutes during power loss. Different from traditional battery-based UPS systems, supercapacitor has a wide operating temperature range and long operating life up to 10 years. Neousys' PB-9250J-110V features -25 to 65°C operating temperature range and extremely high durability.
- Universal standalone power backup module compatible with all box-PCs
- Supports 43-160V wide-range DC input for railway application
- Supercapacitor-based, -40 to 70°C operation for EN 50155 OT4 class conformity
- 9250 watt-second energy capacity
- Maximum 120W output power for the connected back-end system
- Over 10 years lifespan, or 500,000 charge/discharge cycles
- Patented CAP energy management technology
- Extending back-up time in the event of an unforeseen power outage
- Monitoring energy and power consumption to extend operation time for safe system shutdown
- EN 50155 and EN 45545 certificate
Neousys' PB-9250J-110V is a newly designed SuperCAP UPS accepting 110V DC input for fast-growing railway applications. Composed with eight 370F supercapacitor, PB-9250J-110V provides 9250 watt-second stored energy to sustain back-end system from seconds to minutes during power loss. Different from traditional battery-based UPS systems, supercapacitor has a wide operating temperature range and long operating life up to 10 years. Neousys' PB-9250J-110V features -25 to 65°C operating temperature range and extremely high durability.
Thanks to Neousys' patented CAP energy management technology, PB-9250J-110V provides sophisticated features such as real-time energy/ power consumption monitoring, high/low voltage protection, and auto/ manual shutdown control. It automatically manages boot and shutdown to help your system thrive on trains with unstable power source. Additional digital output channels are incorporated for indicating system status such as charging/discharging and power button control.
While computer systems are widely deployed in various railway applications, the rolling stock’s electrical stability still remains a focal point and is crucial for system reliability. PB-9250J-110V can protect the computer or other equipment against power interruption when a train passes through a level crossing or a railroad switch. Furthermore, with its EN 50155 and EN 45545 certificate, PB 9250J-110V can be easily installed and implemented with existing computer/equipment or integrated with onboard power distribution system.
SuperCap UPS Backup Modules
Short Description | View SuperCap UPS Backup Modules Neousys' PB-9250J-110V is a newly designed SuperCAP UPS accepting 110V DC input for fast-growing railway applications. Composed with eight 370F supercapacitor, PB-9250J-110V provides 9250 watt-second stored energy to sustain back-end system from seconds to minutes during power loss. Different from traditional battery-based UPS systems, supercapacitor has a wide operating temperature range and long operating life up to 10 years. Neousys' PB-9250J-110V features -25 to 65°C operating temperature range and extremely high durability. |
---|---|
DIO | 1x 10-pin pluggable terminal block for:
|
Power Input Voltage | 43-160 VDC |
Dimension | 110(W) x 175.2mm(H) x 128.2mm(D) |
Weight | 2.33 kg |
Input Connector | 1x 3-pin pluggable terminal block (V+, GND) |
Mounting | DIN-rail mounting or optional wall-mounting |
Operating Temperature | -40°C ~ 70°C EN50155 OT4 class |
Storage Temperature | -40°C ~ 85°C |
Vibration | Compliant with IEC61373:2010, Category 1, Class B Body mounted (part of EN50155) |
Shock | Compliant with IEC61373:2010, Category 1, Class B Body mounted (part of EN50155) |
EMC | EN 50155:2017, Clause 13.4.8 CE/FCC Class A, according to EN 55032 & EN 55035 |
Operation Voltage | 24 VDC |
Ultracapacitor Configuration | 8x 370F, 3.0V supercapacitors |
Capacity | 9250 watt-second |
Expected Lifespan | >10 years* |
Cycle Life | 500,000 charging/discharging cycles* *To achieve > 10 years lifespan under 24/7 at 70°C operation, please charge PB-9250J-SA to 6525J energylevel using the 4.8x SuperCAP Lifetime Extension setting (please refer to the user manual for details). Once the rated lifetime or cycle life has been reached, the capacity of supercapacitor may decrease up to 30% and ESR may increase up to 100% from initial values. |